Wavelength 180-379 nm
193 | 213 | 248 | 266 | 308 | 325 | 337 | 343 | 351 | 355 | 375 nm

ArF - KrF - XeCl - HeCd - N2 - XeF - Alexandrite
3rd, 4th, 5th of Nd:YAG/YVO4 - Yb:YAG

UV / Excimer 180-379 nm

VAR
VAR
λ [nm]AR (0°); R < methodAR (45°); R < method
193 0.5%   EBE 0.75%   EBE
248 0.25%   EBE 0.75%   EBE
266 0.25%   EBE 0.6%   EBE
355 0.2%   EBE 0.6%   EBE
  0.05-0.1%* low loss IBS 0.1-0.6%* low loss IBS

* depending on price, substrate size and laser power

HR
HR
λ [nm]HR (0°); R > methodHR (45°); R > method
193 96%   EBE 92% (goal 96%)   EBE
  96% (goal 98%) on Fluoride EBE 95% on Fluoride EBE
213 98%   EBE 97%   EBE
248 99.5%   EBE 99%   EBE
266 99.5%   EBE 99.5% standard EBE
  99.5%   IBS 99.5% high power MS
308 99.5%   EBE 99.2%   EBE
  99.7%   IBS 99.7%   IBS
343 99.5%   EBE 99.2%   EBE
351 99.5%   EBE 99.2%   EBE
355 99.5% high power MS 99.5% standard EBE
  99.9% low loss IBS 99.9% low loss IBS
        99.5% high power MS
TFP
TFP
λ [nm] AOImethod
193 Tp > 80%, Ts < 10% 73° EBE
248 Tp > 80%, Ts < 2% Brewster EBE
266 Tp > 90%, Ts < 2% Brewster EBE
355 Tp > 94%, Ts < 2% Brewster EBE
  Tp > 96%, Ts < 0.2% Brewster IBS
VA
VA
λ [nm]0°→ 45°; T = method
193 80% → 10%   EBE
248 90% → 2% standard EBE
  95% → 1% high power MS
266 92% → 1% standard EBE
355 92% → 1% standard EBE
  92% → 1% non-shifting IAD

All values are given for standard coatings. Customized coatings available for all types.

Coating methods available:

EBEIADIPMSIBS
AR 193 nm + 248 nm / 0°
[B-00790]AR 193 nm + 248 nm / 0°

193 nm: R < 0.5%; 248 nm: R < 0.5%

HR 248 nm + 633 nm / 45°
[B-03680]HR 248 nm + 633 nm / 45°

248 nm: R > 99%; 635 nm: R > 98%

R 50% 308 nm / 45°
[B-01937]R 50% 308 nm / 45°

308 nm: R ±3%

TFP 355 nm / 55.9°
[B-11227]TFP 355 nm / 55.9°

355 nm: Tp > 96%, Ts < 0.2% (IBS-coating)

VA 248 nm / 0-45°
[B-07573]VA 248 nm / 0-45°

248 nm: 0° -> 45°; T = 95% -> 1% (MS-coating)

HR 250-350 nm / 0-45°
[B-07720]HR 250-350 nm / 0-45°

250-350 nm: Ravg > 98.5%